A furnace that clicks, hums, then falls silent without heat is failing somewhere in its ignition sequence. On newer systems the usual culprits are a cracked or worn hot surface ignitor, a flame sensor coated in oxide so it cannot prove flame, or a pressure switch that will not close because the flue or condensate line is blocked. On older standing-pilot units, a pilot that lights but will not stay lit usually points to a failing thermocouple or a draft reaching the pilot assembly.

These faults follow a diagnosable order and a professional will work through it rather than replacing parts on guesswork. Repeated ignition lockouts should not be reset over and over, since each attempt puts unburned gas into the chamber. Pro HVAC connects homeowners in Springboro, OH with HVAC professionals. Call (321) 463-9811.

How it works

Four simple steps to Furnace Repair in Springboro, OH

01

Tell us the symptom

Tell us what your system is doing in Springboro, OH.

02

Matched to the fault

We match the symptom to a professional who handles that fault.

03

They contact you

They contact you directly to arrange the visit.

04

If it is not right

If they cannot help, tell us and we find another.

Coverage

Furnace Repair Services Across Springboro, OH

Covering Springboro, OH and nearby ZIPs across Ohio.

Neighborhoods we cover for Furnace Repair

  • Springboro
  • Settlers Walk

ZIP codes we serve

45066
Furnace Ignition And Pilot Light Repair in Springboro, OH

Furnace Ignition And Pilot Light Repair FAQs

Frequently asked questions about Furnace Ignition and Pilot Light Repair

Questions we hear most often about Furnace Ignition and Pilot Light Repair in Springboro, OH.

Talk to a real person
Does my furnace have a reset button and how do I use it?
Many furnaces have a red or yellow reset button on the motor housing or control board. Turn power off at the breaker first, locate the button, and press it once. Restore power and test. Avoid repeated resets, as this can mask a serious problem such as a failing motor or overheating limit switch. In Springboro, OH winters, repeated tripping usually means airflow is blocked or the heat exchanger is cracked.
Why does the pilot light on my furnace keep going out?
A weak thermocouple or drafts around the burner compartment usually cause the pilot to extinguish. First, ensure the furnace door is fully closed and the area around the unit is free of strong air currents. If the pilot still will not stay lit after relighting per the label instructions, turn the gas valve off and do not attempt further adjustments.
Is it safe to run my furnace if it smells like burning?
A burning smell on first startup in fall is often dust burning off the heat exchanger and may clear after a few hours. Persistent or strong odors can indicate overheating or electrical issues. Turn the thermostat down, switch power off at the breaker, and call (321) 463-9811. Do not keep running the unit in Springboro, OH winter conditions if the smell returns.
Do I need an AC recharge, or do I have a refrigerant leak?
A sealed air conditioning system does not use refrigerant up, so if the charge is low there is a leak somewhere. Cooling that weakens season after season, ice on the line set, or a hissing sound near the indoor unit all point to a leak rather than normal top-up. Adding refrigerant without locating the leak means paying again next season, and running low charge makes the compressor run hot. Ask for the leak to be found and quoted before agreeing to a recharge in Springboro, OH.
Why is my ductless mini split not cooling or dripping water?
A mini split head that runs but will not cool usually has a low refrigerant charge from a flare-joint leak, a blocked outdoor coil, or a failed fan or compressor capacitor. Water dripping from the indoor head is almost always the condensate drain, which relies on a gravity fall or a small pump that clogs with biofilm. A blinking timer or operation light is a stored fault code that tells a technician which sensor or board is reporting. In Springboro, OH these units often serve additions, attics and finished basements where they are the only heating or cooling in the room.